- Features & Benefits
Compact DIN 43 880 enclosures – ideally suited to panel
boards
- Surge ratings from
10kA to 150 kA – suitable for service entrance and
branch
- Meets IEC 61643-1 test
classes & CE approved
|
|
|
SGD1100-2S-NE Series
IEC Test Class I; VDE Class B |
|
Imax (8/20) = 140 kA
Iimp (10/350) = 100 kA
UP (In) < 1.5 kV typ.
SGD1100 SPD is designed to offer protection against direct
lightning strikes and is intended for protection in zones
OA-1 to provide equipotential bonding to the building LPS.
Location of use: main distribution boards
|
|
|
DSD1150-2SR Series
IEC Test Class I,II; VDE Class B |
|
In (8/20) =
70 kA
Imax (8/20) = 150 kA
Iimp (10/350) = 25 kA
UP (In) < 1.6 kV typ.
DSD1150 series of SPDs is designed to offer protection
against partial direct and indirect lightning strikes and
are intended for protection in zones OA-1.
Location of use: main distribution boards
Application
The DSD1150 series of surge suppressors provide economical
and reliable protection to primary distribution panel
boards and power distribution systems. They are intended
for locations classified for devices tested to IEC61643-1
test class 1 (or VDE classification B).
Internal thermal disconnect devices ensure safe isolation
during sustained and abnormal events on the distribution
network, or at end-of-life. A visual indicator flag
provides user-feedback in the event of such operation. In
addition, a set of voltage-free contacts is provided for
remote signaling if replacement is due.
Features & Benefits
- 35mm DIN 43 880 profile - matches common circuit
breakers
- Indication flag - provide clear visual indication of
life status
- 150kA 8/20 surge rating provides protection - suitable
for main distribution panels and provides a long
operational life.
- Various operating voltages - to suite most common power
distribution systems.
- Simple combinations of the DSD and SGD series allow the
protection of TT, TNC, TNC-S and IT systems. |
|
|
Single Phase DSD Series 150
kA |
|
Specifications
- Un 110V & 230V
- Uc 150V & 275V
- Imax 150kA 8/20µs
- Non-modular
- Alarm contact standard
- 2M (36mm) width
- Accept 35mm2 conductor (#2 AWG)
-350V, 100kA Spark Gap available
- No alarm contact
|
|
|
DSD1100-1S Series |
|
In (8/20) = 50 kA
Imax (8/20) = 100 kA
Iimp (10/350) = 10 kA
UP (In) < 1.5 kV typ.
DSD1100 series of SPDs is designed to offer protection
against indirect lightning strikes and is intended for
protection in zones OA-1. Protective element is a thermal
disconnect MOV.
Location of use: main distribution boards.
Application
The DSD1100 series of surge suppressors provide economical
protection to primary distribution panel boards and power
distribution systems. They are intended for locations
classified for devices tested to IEC61643-1 test class 1
or 2.
Internal thermal disconnect devices ensure safe isolation
during sustained and abnormal events on the distribution
network, or at end-of-life. A visual indicator flag
provides user-feedback in the event of such operation.
Features & Benefits
- 35mm DIN 43 880 profile - matches common circuit
breakers
- Indication flag - provide clear visual indication of
life status
- 100kA 8/20 surge rating - provides protection suitable
for main/sub-distribution panels and a long operational
life.
- Various operating voltages - to suite most common power
distribution systems. |
|
|
Single
Phase DSD Series 100 kA |
|
Specifications
- Un 110V & 230V
- Uc 150V & 275V
- Imax 100kA 8/20µs
- Modular
- 1M (18mm) width
- Accept 35mm2 conductor (#2 AWG)
No Alarm Contacts
|
|
|
Single
Phase DSD Series 10 – 60 kA |
|
Specifications
- Un 110V, 230V & 400V
- Uc 150V, 275V & 440V
- Imax 10kA, 40kA, 60kA 8/20µs
- 1M (18mm) width
- Accept 35mm2 conductor (#2 AWG)
- 10kA no alarm contacts
- 40kA available with/without alarm contacts
- 60kA alarm contacts (2 flag indicators) |
|
|
DSD160-1SR Series
IEC Test Class II; VDE Class C |
|
In (8/20) = 30 kA
Imax (8/20) = 60 kA
UP (In) < 1.2 kV typ.
DSD160 series of SPDs is designed to offer protection
against indirect lightning strikes and is intended for
protection in zones 1-2. Protective element is a thermal
disconnect MOV.
Location of use: sub-distribution boards.
Application
The DSD160 series of surge suppressors provide economical
and reliable protection to sub-distribution panel boards.
The convenient plug-in module and separate base design,
facilitates replacement of a failed surge module without
needing to undo installation wiring.
Internal thermal disconnect devices ensure safe isolation
during sustained and abnormal events on the distribution
network, or at end-of-life. Visual indicator flags and
voltage-free contacts provide user-feedback in the event
of such operation.
Features & Benefits
- 35mm DIN 43 880 profile - matches common circuit
breakers.
- Indication flags - provide progressive visual indication
of life status.
- Remote contacts (R models) - provide remote status
monitoring.
- 60kA 8/20 maximum surge rating provides protection
suitable for sub-distribution panels and a long
operational life.
- Various operating voltages - to suite most common power
distribution systems. |
|
|
DSD140-1S(R) Series IEC Test Class II; VDE Class C |
|
DSD140-1S(R) Series IEC
Test Class II; VDE Class C
In (8/20) = 15 kA
Imax (8/20) = 40 kA
UP (In) < 1.2 kV typ.
DSD140 series of SPDs is designed to offer protection
against indirect lightning strikes and is intended for
protection in zones 1-2. Protective element is a
disconnect MOV.
Location of use: sub-distribution boards or as close as
possible to a protected device.
Application
The DSD140 series of surge suppressors provide economical
protection to sub-distribution panel boards in locations
classified for
devices tested to IEC61643-1 test class 2 (or VDE
classification C). The convenient plug-in module and
separate base design,
facilitates replacement of a failed surge module without
needing to undo installation wiring.
A visual indicator flag provides user-feedback if the
internal thermal disconnector operates. The “R” series
provides a set of
voltage-free contacts for remote signaling that
maintenance is due.
Features & Benefits
- 35mm DIN 43 880 profile - matches common circuit
breakers
- Indication flag - provide clear visual indication of
life status
- Remote contacts (R models) - provide remote status
monitoring
- 40kA 8/20 maximum surge rating provides protection
suitable for sub-distribution panels and a long
operational life.
- Various operating voltages - to suite most common power
distribution systems.
|
|
|
DSD110-1S(R) Series
IEC Test Class III; VDE Class D |
|
In (8/20) = 5 kA
Imax (8/20) = 10 kA
UP (In) < 0.9 kV typ.
DSD110 series of SPDs is designed to offer protection
against indirect lightning strikes and over-voltages in
induction loops and is intended for protection in zones
1-2.
Protective element is MOV.
Location of use: as close as possible to a protected
device.
Application
The DSD110 series of surge suppressors provide economical
protection to small sub-distribution panel boards or
locations classified
for devices tested to IEC61643-1 test class 2 (or VDE
classification D). They are also ideal for the
installation in wiring termination
boxes at the equipment’s final point-of-use.
The convenient plug-in module and separate base design,
facilitates replacement of a failed surge module without
needing to undo
installation wiring.
Features & Benefits
- 35mm DIN 43 880 profile - matches common circuit
breakers
- Indication flag - provide clear visual indication of
life status
- 10kA 8/20 maximum surge rating - provides protection
suitable for small sub-distribution panels or point-of-use
applications.
- Various operating voltages - to suite most common power
distribution systems.
|
|
|
DSD130-1BR
Series
IEC Test Class II; VDE Class C |
|
In (8/20) = 15 kA
Imax (8/20) = 30 kA
UP (In) < 0.9 kV typ.
* per mode
DSD130-IBS series is designed to offer protection against
indirect lightning strikes and is intended for protection
in zones 1-2.
Protective elements are thermal disconnect MOVs in a
bi-mode configuration.
Location of use: sub-distribution boards or at equipment.
Provides L-G and N-G protection.
Application
The DSD130 series of surge suppressors provide economical
and reliable protection from voltage transients on power
distribution
systems. Each module provides two modes of protection L-G
and N-G in a conveniently 35mm DIN package suitable for
sub-distribution panel boards.
Internal thermal disconnect devices ensure safe isolation
during sustained and abnormal events on the distribution
network, or at
end-of-life. A visual indicator flag and voltage-free
contacts provide user-feedback in the event of such
operation.
Features & Benefits
- 35mm DIN 43 880 profile - matches common circuit
breakers.
- Indication flag and remote status monitoring contacts -
provide clear visual indication of life status.
- 30kA 8/20 per pole maximum surge rating - provides
protection suitable for small sub-distribution panels and
a long operational
life.
- Two modes of protection: L-G, N-G.
- Various operating voltages - to suite most common power
distribution systems.
|
|
|
DSD 3
Phase Series
IEC Test Class I,II; VDE Class B |
|
Application
The DSD 340 and 380 series of surge suppressors provide
protection to 3 phase primary and secondary distribution
panel boards. Models are available for TN-C, TN-S, TN-C-S,
IT and TT and power distribution systems. They are
intended for locations classified for devices tested to
IEC61643-1 test class I and II (or VDE classification B).
Specifications
- Un 230V
- Uc 275V
- Imax 40kA & 80kA 8/20µs per phase
- TNC, TNS, TT system support
- Alarm contacts
- Non-modular
- 4M (72mm) width
- Accept 35mm2 conductor (#2 AWG)
- 80kA available in low leakage version
- New plastic injection available August |
|
|
DSD380
Series IEC Test Class I,II; VDE Class B |
|
In (8/20) = 40 kA /phase
Imax (8/20) = 80 kA /phase
Iimp (10/350) = 25 kA /phase
UP (In) < 1.6 kV typ.
DSD 380 series of SPDs is designed to offer protection
against direct and indirect lightning strikes and is
intended for protection in zones 0A – 1.
Location of use: TN-C, TN-S ,TT 3 phase main distribution
boards
|
|
|
DSD340
Series IEC Test Class II; VDE Class B |
|
In (8/20) = 20 kA /phase
Imax (8/20) = 40 kA /phase
Iimp (10/350) = 5 kA /phase
UP (In) < 1.6 kV typ.
DSD 340 series of SPDs is designed to offer protection
against indirect lightning strikes and is intended for
protection in zones 1 - 2.
Location of use: TN-C, TN-S ,TT 3 phase branch
distribution boards
|